If you’ve ever had an MRI scan, you know that it can be hard to lie still in the noisy, claustrophobic scanner. People often move involuntarily, requiring scientists to correct or eliminate the imaging data during movement.
Recently, a collaboration of Rutgers University and Columbia University researchers used this seemingly unhelpful data to further their understanding of a neurodevelopmental disease.
“We asked ourselves, ‘What could these involuntary movements, which researchers usually consider a nuisance, tell us about autism?’” Elizabeth Torres, PhD, an associate professor of cognitive psychology at Rutgers, said in a news release.
The neuroscientists analyzed functional magnetic resonance imaging (fMRI) data from 1048 participants, aged 6 to 50 years old, including individuals with autism spectrum disorders and healthy controls. The data was publicly available primarily through the Autism Brain Imaging Data Exchange databases.
The researchers determined that people with autism had more problems controlling their head movements than healthy controls. They also found that motor control problems were exacerbated with the presence of secondary neuropsychiatric diagnoses, lower verbal and performance intelligence and autism severity, as reported in a recent paper in Scientific Reports.
“For the first time, we can demonstrate unambiguously that motor issues are core issues that need to be included in the diagnosis criteria for autism,” Torres said in the release.
In addition, they found that psychotropic medications, commonly used to treat people on the autism spectrum, were associated with lower levels of motor control. These medications include anti-convulsants and anti-depressants. Autistic people who were taking more than one psychotropic medication moved the most during the fMRIs, and their movement worsened over the scanning session.
The researchers conclude in their paper, “Nevertheless, it remains to be demonstrated if changes in head micro-movements directly capture targeted changes in symptomology brought about by a specific medication.” Their findings are also complicated by the simultaneous presence of autism and other diseases, such as attention deficit hyperactivity disorder. So more research is needed.
Source:
http://scopeblog.stanford.edu/2016/12/28/motor-control-problems-may-be-core-issue-for-people-with-autism/
Wednesday, January 18, 2017
Top 3 Dental laboratory handpieces and micro motors list
Dental laboratory handpieces and motors are one of the most used equipment in a dental lab; so choosing the best one for your practice should be carefully considered. There is a large number of dental laboratory handpieces and their corresponding motors on the market. Features vary from handpiece to handpiece but can include; all-in-one turbine, air nozzle and spray, reduced weight and ergonomic design, whisper quiet/ no vibration, high torque, fiberoptics and smooth transitioning while increasing or decreasing rpm’s. When choosing a dental laboratory handpiece and motor, consider what features that will be most beneficial to your dental lab as well as what materials your lab works with most frequently.
Most dental laboratory motors come with a corresponding handpiece , however, many vendors also offer a variety handpieces for each motor. Dental laboratory motors are often controlled via foot pedal, although some do offer a hand dial. If space is an issue, there are wall mounted motors. If mobility is important, there are also lightweight compact motors.
Most dental laboratory motors come with a corresponding handpiece , however, many vendors also offer a variety handpieces for each motor. Dental laboratory motors are often controlled via foot pedal, although some do offer a hand dial. If space is an issue, there are wall mounted motors. If mobility is important, there are also lightweight compact motors.
Pozzi Muscle U 2009 BlueSky Complete Laboratory Handpiece
American Tooth Industries
- Warranty: Not Available
- RPM Range: Not Available
- Torque: Not Available
Power-Tip Lab Handpiece
Aseptico, Inc.
- Warranty: Not Available
- RPM Range: Not Available
Compare for selected.Torque Plus - AEU-12C Lab Handpiece
Aseptico, Inc.
- Warranty: Not Available
- RPM Range: Not Available
- Torque: High
Thursday, January 5, 2017
Where to Find a Reliable Electric Brushless Lab Micro Motor Store
Looking for a Reliable Electric Brushless Lab Micro Motor ?
Then look no further!
We’ve been repairing Electric Lab Micro Motors (KaVo, MUSS, Schick, NSK, etc…) for over 15 years and during this time we’ve seen the technological and reliability advancements that the Korean Saeshin company has been making. We’re very impressed and you’ll be even more impressed.
Saeshin OZ Black Brushless Electric Micro Motor for Dental Lab Professionals
Made in Korea with quality parts and German Bearings
12 Month Warranty
MAX speed: 50,000 RPM
Torque: Strong 7.8N.cm
Placement: Vertical or Horizontal
Input: 220-~240V 50/60Hz
Output: 230w
Direction: Forward and Reverse
Lower ongoing repair and servicing costs
Saeshin OZ Black Electric Lab Brushless Micro Motor Technical Diagram
See more:
http://www.dentalcompare.com/Restorative-Dentistry/4608-Dental-Laboratory-Handpieces-and-Motors/
Then look no further!
We’ve been repairing Electric Lab Micro Motors (KaVo, MUSS, Schick, NSK, etc…) for over 15 years and during this time we’ve seen the technological and reliability advancements that the Korean Saeshin company has been making. We’re very impressed and you’ll be even more impressed.
Saeshin OZ Black Brushless Electric Micro Motor for Dental Lab Professionals
Made in Korea with quality parts and German Bearings
12 Month Warranty
MAX speed: 50,000 RPM
Torque: Strong 7.8N.cm
Placement: Vertical or Horizontal
Input: 220-~240V 50/60Hz
Output: 230w
Direction: Forward and Reverse
Lower ongoing repair and servicing costs
Saeshin OZ Black Electric Lab Brushless Micro Motor Technical Diagram
See more:
http://www.dentalcompare.com/Restorative-Dentistry/4608-Dental-Laboratory-Handpieces-and-Motors/
Wednesday, January 4, 2017
Dental Laboratory Micro Motors - Combi 24 "E" Type Dental Micro Motor
Combi 24 "E" Type Dental Micro Motor
High quality, light and compact handpiece (DC 24V).
Ergonomic design with handpiece cradle.
No noise, vibration or heat after long hours of operation.
On/Off foot pedal
1 year warranty
Easy Operation with Power-Speed Control Combined Switch.
Selectable Forward Reverse rotation and Variable speed control knob.
Long Continuous Operation.
Light weight Controller.
E-Type Motor with Straight Attachment Included.
Excepts Both 110 & 220 Volt
Base Unit
VOLTAGE CYCLE AMP R.P.M DIMENSION(mm) WEIGHT
110/230V 50/60Hz DC 24V
/1.3A Hand piece
Max. W D H 882(g)
117 154 72
Handpiece
MODEL NONLOAD
R.P.M MAX TORQUE
(gf-Cm) ELECTRIC
POWER(W) WELGHT
(g) DIMENSION(mm)
L D
SDE-MH24E 0-20,000 80 70 96 20
370
http://handpiecerepair.com.au/perths-best-dental-handpiece-and-lab-micro-motor-repair-service/
Advantages and Disadvantages of Electric Micromotor Dental Units
Electric micromotor dental units are available alone, as slow speed handpieces for polishing and drilling, or combined with an ultrasonic scaler.
How It Works
The electric micromotor dental unit can polish or cut. The handpiece is driven by an electric motor in the handle. The polishing cup, or bur, can variably rotate from 0 to 30,000 rpm and go forward or reverse. It provides a very high torque. The handpiece can take a prophy angle, with polishing cups, or a contra-angle, with various attachments, including RA burs and polishing cups. Only a few units have a water-cooling facility.
Long HP burs can also be used in the nose cone (when the prophy angle is removed). They are used principally for trimming small herbivore cheek teeth.
Advantages
Relatively inexpensive, compared with an air driven unit.
Generally small, compact and mobile.
Disadvantages
Very slow in dental terms therefore extremely limited efficiency.
Burs 'walk off' teeth during cutting, due to slow speed.
Handpieces vibrate and heat up after a few minutes.
The torque is high. This is an advantage when polishing but a severe disadvantage for drilling tissues which will not be removed (e.g. bones).
How It Works
The electric micromotor dental unit can polish or cut. The handpiece is driven by an electric motor in the handle. The polishing cup, or bur, can variably rotate from 0 to 30,000 rpm and go forward or reverse. It provides a very high torque. The handpiece can take a prophy angle, with polishing cups, or a contra-angle, with various attachments, including RA burs and polishing cups. Only a few units have a water-cooling facility.
Long HP burs can also be used in the nose cone (when the prophy angle is removed). They are used principally for trimming small herbivore cheek teeth.
Advantages
Relatively inexpensive, compared with an air driven unit.
Generally small, compact and mobile.
Disadvantages
Very slow in dental terms therefore extremely limited efficiency.
Burs 'walk off' teeth during cutting, due to slow speed.
Handpieces vibrate and heat up after a few minutes.
The torque is high. This is an advantage when polishing but a severe disadvantage for drilling tissues which will not be removed (e.g. bones).
Thursday, December 29, 2016
Automotive Micro Motor Market Research Report Now Available at Research Corridor
Research Corridor has published a new research study titled “Automotive Micro Motor Market – Growth, Share, Opportunities, Competitive Analysis and Forecast, 2015 – 2022”. The Automotive Micro Motor market report studies current as well as future aspects of the Automotive Micro Motor Market based upon factors such as market dynamics, key ongoing trends and segmentation analysis. Apart from the above elements, the Automotive Micro Motor Market research report provides a 360-degree view of the Automotive Micro Motor industry with geographic segmentation, statistical forecast and the competitive landscape.
Browse Full Report with TOC: http://www.researchcorridor.com/automotive-micro-motor-market/
Geographically, the Automotive Micro Motor Market report comprises dedicated sections centering on the regional market revenue and trends. The Automotive Micro Motor market has been segmented on the basis of geographic regions into North America, Europe, Asia Pacific and Rest of the World (RoW). The RoW segment consists Latin America and the Middle East & Africa. The Automotive Micro Motor market has been extensively analyzed on the basis of various regional factors such as demographics, gross domestic product (GDP), inflation rate, acceptance and others. Automotive Micro Motor Market estimates have also been provided for the historical years 2013 & 2014 along with forecast for the period from 2015 – 2022.
The research report also provides a comprehensive understanding of Automotive Micro Motor market positioning of the major players wherein key strategies adopted by leading players has been discussed. The Automotive Micro Motor industry report concludes with the Company Profiles section which includes information on major developments, strategic moves and financials of the key players operating in Automotive Micro Motor market.
Holden teases trio of limited edition Commodores ahead of January reveal
Hard-core Holden fans shouldn't take holidays in January.
The Aussie car maker has just released details of a micro-site that confirms a trio of limited edition Commodores will be sold in 2017 to mark the final year of local production for the iconic muscle car.
The site (www.holden.com.au/cars/commodore/limited-edition) is due to go live this afternoon (Thursday December 15) and features three vehicles under cover with confirmation they are based on the SS-V Redline sedan and ute and the Calais V sedan. It asks for expressions of interest from customers wishing to secure a piece of motoring history.
While Holden has yet to reveal official details of the models, the main image showcases a black set of alloy wheels featuring a unique red ring around the outer edge of the rim, a matching red highlight on the lower portion of the front intake and a black bonnet vent on another vehicle in the foreground.
Reports have suggested Holden will dip into its back catalogue and revive badges such as Director and Magnum - previously used on HDT Special Vehicles models back in the 1980s - as a celebration of the Commodore's performance heritage.
The original HDT Director was created by Holden hero Peter Brock to be considered among the most luxurious sports sedans of its time. It featured a unique independent rear suspension system, upgraded V8 engine and a high-grade interior that even included a portable phone and fax machine, which was at the absolute cutting edge of connectivity back in 1987.
But it was also fitted with the controversial Energy Polariser - a box of crystals that Brock claimed improved performance and reduced fuel consumption - that ultimately led to Holden dumping its Bathurst legend.
HDT also used the Magnum name on a high-performance version of the WB Caprice limousine or one-tonne ute.
Accordingly, it is expected the Director name could be used on the more luxury-focused Calais V (without a Polariser) while the Magnum could be reserved for the ute. It has been suggested that the third model will be a track-focused variant of the SS-V Redline sedan that has been created to pay homage to the Commodore's vast successes in motorsport over the last 38 years, from its 24 Bathurst victories to the Repco Round Australia Reliability Trial win and the King's Cup crown in the 1986 FIA Touring Car Championship.
Holden promises to reveal the official information in January, the day the vehicles are expected to be officially on-sale to the public. Commodore fans should save the date...
Subscribe to:
Posts (Atom)


